ShieldOut, what is?
ShieldOut is a patented material that offers
breathability and superior protection at a substantially lower cost point than
that of the major manufacturers and represents an advance in material
development.
But what is
it?
ShieldOut is made
from two materials "married" together. The first material is a specially
designed polypropylene textile that makes the material strong and hard to
"punch through". The second material is a film that has very small holes in it.
(These holes will not permit chemicals to pass through but will permit oxygen
to pass through and that is why it is "Breathable").
Also since the
film is Polyethylene it means that the outside of the suit is resistant to most
chemicals and will not "wet out". The interior material will transport "sweat"
away from the wearer making it unique from the other products where moisture
"pools" and drips.
What this means to the end user is a product that is reliable, breathable and functional with all of the cost benefits.
|
|
Units |
Sample Results |
Test Procedure PGI Standard |
Reference Test Procedure ASTM Standard |
|
|
||||
|
|
||||
|
Basis Weight |
oz./yd. |
1.5 |
D3776 |
D3776 |
|
|
|
|
|
|
|
Thickness |
mils. |
6.77 |
D1777 |
D1777 |
|
|
|
|
|
|
|
Strip Tensile (MD/CD) |
lbs./in. |
8.73/6.22 |
D1682 |
D1682 |
|
|
|
|
|
|
|
Strip Elongation (MD/CD) |
% |
112/107 |
D1682 |
|
|
|
|
|
|
|
|
Work to Break (MD/CD) |
in. - lbs. |
20.38/12.13 |
D1682 |
D1682 |
|
|
|
|
|
|
|
Work up to Fmax. (MD/CD) |
in. - lbs. |
18.55/10.83 |
D1682 |
|
|
|
|
|
|
|
|
Tongue Tear (MD/CD) |
lbs. |
15.25/9.62 |
|
D2261 |
|
|
|
|
|
|
|
Flammability |
|
Class1 |
|
CS-191-53, Sec. 1610 |
|
|
|
|
|
|
|
Mullen Burst |
lbs./sq. in. |
83 |
|
|
|
|
|
|
|
|
|
Particulate Burden |
|
none |
|
|
|
|
|
|
|
|
|
Shrink Temperature |
F/Centigrade |
270/132 |
|
|
|
|
|
|
|
|
|
Melt Temperature |
F/Centigrade |
275/135 |
|
|
|
|
|
|
|
|
|
Water Vapor Transmission |
grams/24 Hours |
1500 |
|
|
What chemicals
is it resistant against?
Our company knows
that the best approach to prove that we know what we are talking about is to
have independent testing done on the product. We specifically contracted an independent
laboratory to prove that the chemical resistance was what the industry expected
against the know standards. The results
showed that;
|
Bleach 5% |
ASTM T903 |
Pass |
|
Hydraulic Jack Oil |
ASTM T903 |
Pass |
|
Isocyanate Based Paint Hardener |
ASTM T903 |
Pass |
|
Motor Oil |
ASTM T903 |
Pass |
|
Sodium hydroxide |
ASTM T903 |
Pass |
|
Mineral Oil |
ASTM T903 |
Pass |